Accessibility Tools

Skip to main content

LR-Cal LTC-DB-1100-44
Metal dry block temperature calibrator
+200...+1100°C

LR-Cal LTC-DB-1100-44 dry block temperature calibrator
LR-Cal
  • Portable metal dry block temperature calibrator
  • Range +200°C...+1100°C
  • Accuracy ±3°C, stability ±0.05°C
  • Dry block: 44 mm diameter
    Immersion depth: 220 mm
LR-Cal LTC-DB-1100-44 with option LTC-MP-3I (3 measuring inputs)

Easy operation via touchscreen and electrical connections of the optional version with 3 measuring inputs

Diagram of customer-specific block inserts for LR-Cal LTC-DB-1100-44

Diagram of customer-specific block inserts for
LR-Cal
LTC-DB-1100-44

Less thermal stress for test items at the LR-Cal LTC-DB-1100-44

Less thermal stress

LR-Cal LTC-DB-1100-44 options + further accessories

3 configurable
measurement inputs

Code: LTC-MP-3I
LTC-MP-3I

Option, must be ordered together with the basic device:
Device version with 3 configurable measurement inputs
2 x for Pt 100 / Pt 1000 / thermocouples
1 x for analog signal 4-20mA / 0-10V

Power supply
115 VAC

Code: LTC-MP-115V
LTC-MP-115V

Option, must be ordered together with the basic device:
Device version for power supply
115 VAC 50/60 Hz
(instead of 230 VAC)
NO extra charge

DAkkS
calibration certificate

Code: DKD-T-KAL-TK-6T
DKD-T-KAL-TK-6T

Option:
DAkkS calibration certificate
for the measuring chain consisting of calibrator display and internal reference sensor, 6 measuring points

PC software
Aq2Sp2

Code: LTC-AQ2SP2
LTC-AQ2SP2

Accessory:
Windows PC software Aq2Sp2
Download version

Sturdy
hard-shell case

Code: LTC-DB-AKOFFER
LTC-DB-AKOFFER

Accessory:
Sturdy aluminum storage and transport case
with space for device and accessories
Dimensions 50 x 37 x 60 cm

Sturdy
trolley case

Code: LTC-DB-TROLLEY
LTC-DB-TROLLEY

Accessory:
Sturdy hard-shell trolley case with extendable handle and wheels
with space for device and accessories
Dimensions 43 x 32 x 55 cm

Block insert
removal tool

Code: LTC-DB-TW
LTC-DB-TW

Spare part:
Tool for removing metal block inserts
(1 piece already included in the device delivery)


Suitable reference sensors for device version with option LTC-MP-3I (3 configurable measurement inputs):

External Pt 100 reference sensors, see LR-Cal LRT-F (Pt 100)...

External reference thermocouple, see LR-Cal LRT-F (TC)...

Explanations regarding metal dry block temperature calibrators

The test object (all types of temperature measuring devices, e.g., dial thermometers, resistance thermometers, temperature switches, thermostats, etc.) and the reference temperature measuring device (built into the calibrator or external reference) are subjected to the same test temperatures. The measured values of the reference are compared with the values of the test item. This allows conclusions to be drawn not only about the function of the test item, but also about its measuring accuracy and measured value deviation.

Please note that the information specified in the respective technical data regarding radial and axial temperature uniformity refers to specific immersion depths and may not apply to all immersion depths in every case. The temperature range specifications apply at an ambient temperature of +20°C.

The LR-Cal metal dry block temperature calibrators have an internal (built-in) reference. If its accuracy is insufficient, an external reference (with or without its own display) can be used.

The LTC-MP-3I option can be ordered for the LR-Cal metal dry block temperature calibrators. This provides 3 measurement inputs, 2 of which are for resistance thermometers or thermocouples and 1 of which is for analog signals (4-20 mA or 0-10 V). Here, you can connect, for example, a test object and an external reference sensor, or 2 test objects and a temperature transmitter. The values of these connected sensors are shown on the calibrator's display.

Furthermore, the LR-Cal Aq2Sp2 PC software is available as an accessory for the LR-Cal metal block temperature calibrators. This software can be used to control the calibrator via its USB interface, perform manual or automatic calibration of one or more test objects, load and endurance tests, thermostat tests, and create calibration certificates.
Synonyms

Metal block temperature calibrators are also referred to as

  • Block temperature calibrator
  • Dry well temperature calibrator
  • Metal block temperature calibrator
  • Temperature calibration oven
  • Temperature calibrator
  • Temperature calibration device
  • Temperature calibration oven