LR-Cal LTC-DB-1200-35
Metal dry block temperature calibrator
+200...+1200°C
Description
LR-Cal LTC-DB-1200-35 description
The LR-Cal LTC-DB-1200-35 metal dry block temperature calibrator serves as both a temperature source and reference device for testing and calibrating all types of temperature measuring instruments.
- Temperature range +200°C...+1200°C
- Homogeneous temperature distribution
- Easy operation with color touchscreen
- Ramp function + thermostat tests
- Computer-controlled calibrations via USB interface and optional LR-Cal Aq2Sp2 software for MS Windows® PCs
- Numerous block inserts with different bores available for different test objects
Less thermal stress for your test specimens
The LR-Cal LTC-DB-1200-35 metal dry block temperature calibrator is equipped with a counterflow forced ventilation system that keeps the temperature in the upper part of the calibrator very low. This solution makes it possible to keep the connection head or housing of the device under test very close to room temperature.
It also ensures a high level of safety for the operator, as the temperature of the grille on the top of the housing remains very low.
The figure shows a thermocouple as a test object in an LR-Cal LTC-DB-1200-35 at 1,000°C. The temperature of the connection head of the test object, measured with an optical pyrometer, is only 37.7°C, which is very close to room temperature. This test confirms the excellent insulation of this calibrator.
Specification
LR-Cal LTC-DB-1200-35 specification
| Description: | Data: | |
|---|---|---|
| Temperature range: | +200...+1200°C | |
| Display: | Touchscreen (color) | |
| Display accuracy: | ±3°C full temperature range * | |
| Units of measure: | °C / °F / K | |
| Display resolution: | 0,1° / 0,01° / 0,00^° | |
| Mean heating time: (incl. stabilization) |
approx. 60 min. from ambient temperature to +1000°C |
|
| Mean cooling time: (incl. stabilization) |
approx. 330 min. from +1000°C to +100°C |
|
| Stability: | ±0.05°C | |
| Axial uniformity: | 1.5°C ±0.8 ** | |
| Radial uniformity: | ±0.5°C *** | |
| Hole (block) diameter: | 35 mm | |
| Hole (block) depth: | 210 mm | |
| Insert material: | Ceramics (optional Inconel) | |
| Switch test; voltage: | Open/Closed; 4.5 VDC | |
| Adjustable ramp function: | from 0.1°C/min | |
| PC interface: | USB type B | |
| Automatic calibration: | at 5 temperature points | |
| External probes: | not available for LR-Cal LTC-DB-1200-35 | |
| Operating voltage: | 230 VAC 50/60 Hz | |
| Electric power: | 900 W | |
| Dimensions: | 160 x 350 x 385 mm | |
| Weight incl. std. accessories: | 11.5 kg | |
All values have been measured at ambient temperature of +20°C.
The achievement of stabilization is confirmed by a displayed root symbol and an audial beep.
* = Temperature deviation between display and reference probe.
** = Max. temperature difference at stable temperature over 30 min.
*** = Measured at 1000°C at 40 mm above the button.
Standard scope of delivery
LR-Cal LTC-DB-1200-35 standard scope of delivery
- Portable metal block temperature calibrator LR-Cal LTC-DB-1200-35
- Spare fuses
- Power supply cable
- Connection cable for thermostat tests
- 1 block insert 35 x 160 mm made of ceramic, with 4 holes: 4.8 + 6.4 + 9.5 + 12.8 mm diameter (depth 125 mm)
- 1 tool for removing block inserts
- Acceptance test certificate 3.1 in accordance with DIN EN 10204 (factory calibration certificate)
- Operating instructions DE+EN
Available dry block inserts
LR-Cal LTC-DB-1200-35 available block inserts
Outer dimension: 35 x 160 mm (usable immersion depth 125 mm)
| • Block inserts and upper insulation with standard holes: | |||
|---|---|---|---|
| Order-Code: | Number of holes | Material | Bock inserts with standard holes |
| LTC-BI-35-160-4C | 4 | Ceramics | 4.8 + 6.4 + 9.5 + 12.8 mm diameter |
| (1 x included in standard scope of delivery of the calibrator) | |||
| LTC-BI-35-160-4I | 4 | Inconel 600 | 4.8 + 6.4 + 9.5 + 12.8 mm diameter |
| Order-Code: | Number of holes | Upper insulation (Duratec), with standard holes | |
| LTC-ID-35-4 | 4 | suitable for LTC-BI-35-160-4C + LTC-BI-35-160-4I | |
| (1 x included in standard scope of delivery of the calibrator) | |||
| • Block inserts and upper insulation with customer-specific holes: | |||
| Order-Code: | Number of holes | Material | Block insert |
| LTC-BI-35-160-C1 | as per customers request | Keramik | according to customer requirements, please ask for advice |
| LTC-BI-35-160-I1 | as per customers request | Inconel | according to customer requirements, please aks for advice |
| Order-Code: | Number of holes | Upper insulation (Duratec) | |
| LTC-ID-35-C | as per customers request | as per customers request, suitable to block insert | |
Block inserts in Ceramics:
Block insert in Inconel:
Upper insulation in Duratec:
LR-Cal LTC-DB-1200-35 options + further accessories
DAkkS certificate
Option:
DAkkS calibration certificate
for the measuring chain consisting of calibrator display and internal reference sensor, 6 measuring points
PC software
Aq2Sp2
Accessory:
Windows PC software Aq2Sp2
Download version
Sturdy
hard-shell case
Accessory:
Sturdy aluminum storage and transport case
with space for device and accessories
Dimensions 50 x 37 x 60 cm
Sturdy
trolley case
Accessory:
Sturdy hard-shell trolley case with extendable handle and wheels
with space for device and accessories
Dimensions 43 x 32 x 55 cm
Block insert
removal tool
Spare part:
Tool for removing metal block inserts
(1 piece already included in the device delivery)
The test object (all types of temperature measuring devices, e.g., dial thermometers, resistance thermometers, temperature switches, thermostats, etc.) and the reference temperature measuring device (built into the calibrator or external reference) are subjected to the same test temperatures. The measured values of the reference are compared with the values of the test item. This allows conclusions to be drawn not only about the function of the test item, but also about its measuring accuracy and measured value deviation.
Please note that the information specified in the respective technical data regarding radial and axial temperature uniformity refers to specific immersion depths and may not apply to all immersion depths in every case. The temperature range specifications apply at an ambient temperature of +20°C.
The LR-Cal metal dry block temperature calibrators have an internal (built-in) reference. If its accuracy is insufficient, an external reference (with or without its own display) can be used.
Furthermore, the LR-Cal Aq2Sp2 PC software is available as an accessory for the LR-Cal metal block temperature calibrators. This software can be used to control the calibrator via its USB interface, perform manual or automatic calibration of one or more test objects, load and endurance tests, thermostat tests, and create calibration certificates.
Synonyms
Metal block temperature calibrators are also referred to as
- Block temperature calibrator
- Dry well temperature calibrator
- Metal block temperature calibrator
- Temperature calibration oven
- Temperature calibrator
- Temperature calibration device
- Temperature calibration oven