Pressure switcheselectronic + mechanical
-
Electronic pressure switches with up to 4 switching points
- with or without digital display
- easy handling
- Switching points and hysteresis freely configurable
- Switching delay adjustable
- min-/max-value memory -
Mechanical pressure switches with up to 2 switching points
- with diaphragm or Bourdon tube system
- particularly robust
Electronic pressure switches
With or without digital on-site display
LDS 350-IO
Sensor: stainless steel
from 0...100 mbar to 0...600 bar
Accuracy ±0.5%/±0.35% FS
DS 400
Sensor: stainless steel
from 0...100 mbar to 0...600 bar
Accuracy ±0.25%/±0.35% FS
DS 401
Sensor: ceramics
from 0...400 mbar to 0...600 bar
Accuracy ±0.5% FS
DS 200
Sensor: stainless steel
0...100 mbar to 0...600 bar
Accuracy ±0.25%/±0.35% FS
LED display 4-digit, rotatable
Configurable
Option: accuracy ±0,25% FS
Option: different pressure connections
For universal applications
LED display 4-digit, rotatable
Configurable
Options:
Ex version Ex ia
Welded sensor
For universal applications
LED display 4-digit, rotatable
Configurable
Options:
Ex version Ex ia
Process connection made of PVDF
For universal applications
LED display 4-digit, rotatable
Configurable
Options:
Ex version Ex ia
Welded sensor
Analog output
Simulation software:
A Windows PC software is available for DOWNLOAD to simulate the functions and setting options.
DS 201
Sensor: ceramics
0...400 mbar to 0...600 bar
Accuracy ±0.5% FS
DS 202
Sensor: stainless steel, welded
0...6 to 0...600 bar
Accuracy ±0.5% FS
DS 210
Sensor: stainless steel,
without media separation
0...10 mbar to 0...1 bar + vacuum
Accuracy ±0.25%/±0.35% FS
DS 214
Sensor: stainless steel, welded
0...600 to 0...2,200 bar
Accuracy ±0.35% FS
For universal applications
LED display 4-digit, rotatable
Configurable
Options:
Ex version Ex ia
Process connection made of PVDF
Simulation software:
With DOWNLOAD a Windows PC software is available to simulate the functions and setting options.
For medical technology and oxygen applications
LED display 4-digit, rotatable
Configurable
Options:
Ex version Ex ia
Oxygen applications
Simulation software:
With DOWNLOAD a Windows PC software is available to simulate the functions and setting options.
For heating, ventilation and air conditioning technology
LED display 4-digit, rotatable
Configurable
Options:
Ex version Ex ia
Simulation software:
With DOWNLOAD a Windows PC software is available to simulate the functions and setting options.
For plant and mechanical engineering
LED display 4-digit, rotatable
Configurable
Options:
Adjustability of zero and span
Simulation software:
With DOWNLOAD a Windows PC software is available to simulate the functions and setting options.
DS 217
Sensor: stainless steel, welded
0...6 to 0...600 bar
Accuracy ±0.5% FS
DS 230
Sensor: ceramics
0...2 to 0...400 bar
Accuracy ±1.5% FS
DS 200P
Sensor: stainless steel, front-flush
0...100 mbar to 0...40 bar
Accuracy ±0.25%/±0.35%/±0.5% FS
DS 201P
Sensor: stainless steel, front-flush
0...60 to 0...400 bar
Accuracy ±0.5% FS
For hydraulic and oxygen applications
1 analog output and up to 2 switching outputs
LED display 4-digit, rotatable
Configurable
Options:
Oxygen version
Simulation software:
With DOWNLOAD a Windows PC software is available to simulate the functions and setting options.
For pneumatic and hydraulic applications
LED display 4-digit, rotatable
Configurable
Options:
Analog output
Simulation software:
With DOWNLOAD a Windows PC software is available to simulate the functions and setting options.
For hygienic applications
LED display 4-digit, rotatable
Configurable
Options:
Ex version Ex Ia
Analog output
Simulation software:
With DOWNLOAD a Windows PC software is available to simulate the functions and setting options.
For hygienic applications
LED display 4-digit, rotatable
Configurable
Options:
Ex version Ex Ia
Temperature decoupler up to 300°C
Simulation software:
With DOWNLOAD a Windows PC software is available to simulate the functions and setting options.
DS 400P
Sensor: stainless steel, front-flush
0...100 mbar to 0...40 bar
Accuracy ±0.25%/±0.35% FS
DS 4
Sensor: silicium
0...1 to 0...100 bar + vacuum
Accuracy ±1% FS
DS 6
Sensor: ceramics
0...2 to 0...400 bar
Accuracy ±1% FS
Programming device P6
Easy programming e.g. of the DS 6 pressure switch, independent of the PC
For hygienic applications
LED display 4-digit, rotatable
Configurable
Options:
Ex version Ex Ia
Analog output
Analog output with turn-down 1:5
For pneumatic applications
Compact, without display
1 or 2 switching outputs
For hydraulic applications
Compact, without display
1 or 2 switching outputs
Programmable with programmer P6
Fast connection between supply and pressure switch
Up to 5 configurations can be stored and copied
All pressure switch parameters editable
Sturdy plastic housing with 4-digit LED display
Mechanical pressure switches
Particularly robust, with diaphragm or bourdon tube system
03.10
with diaphragm system
0...1 to 0...25 bar + vacuum
1 micro-swith SPDT
Threaded connection
Switching hysteresis:
fixed or adjustable
Low-Cost
03.27
with diaphragm system
0...6 mbar to 0...160 bar + vacuum
1 or2 micro-switches SPDT
Thread or flange
Switching hysteresis:
fixed or adjustable
03.30
with bourdon tube system
0...10 to 0...600 bar + Vakuum
1 or 2 micro-switches SPDT
Threaded connection
Switching hysteresis:
fixed or adjustable
03.40 + 03.45
with diaphragm system
0...40 mbar to 0...160 bar + vacuum
1 or 2 micro-switches SPDT
Thread or flange
Switching hysteresis:
fixed or adjustable
Ex db IIC T6 Ex tb IIIC T85°C