Skip to main content
TEMPERATURE CALIBRATION

Temperature
calibration baths

LR-Cal

Portable and stationary temperature calibration baths as controlled temperature source for temperature comparison calibrations

LR-Cal FLUID 100-N
Portable
Range -18...+140°C
Accuracy ±0.15°C
Stability ±0.02°C
Option: dry well inserts

LR-Cal FLUID 100-45
Portable
Range -35...+140°C
Accuracy ±0.15°C
Stability ±0.02°C

LR-Cal LTC 100-F
Portable
Range -35...+160°C
Accuracy ±0.1°C
Stability ±0.01°C
Option: dry well inserts
Option: exchangeable calibration bath inserts

LR-Cal LTC 100-F-PLUS
Portable
Range -40...+160°C
Accuracy ±0.1°C
Stability ±0.01°C
Option: exchangeable calibration bath inserts

LR-Cal FLUID 200
Portable
Range: ambient...+200°C
Accuracy ±0.15°C
Stability ±0.02°C
Option: Dry well inserts

LR-Cal LTC 200-F
Portable
Range +30...+225°C
Accuracy ±0.1°C
Stability ±0.01°C
Option: dry well inserts
Option: exchangeable calibration bath inserts

LR-Cal FLUID 200-H
Portable
Range: ambient...+250°C
Accuracy ±0.2°C
Stability ±0.02°C
Option: dry well inserts

LR-Cal BK 40-M
Stationary
Range -40...+125°C
Accuracy ±0.2°C
Stability ±0.05°C
Option: vertical overflow system

LR-Cal TB 300-M
Stationary
Range +50...+300°C
Accuracy ±0.2°C
Stability ±0.05°C
Option: vertical overflow system

What is temperature calibration with a temperature calibration bath?

What is temperature calibration with a temperature calibration bath?

The test item (temperature measuring instruments of all types, e.g. dial thermometers, glass thermometers, resistance thermometers, temperature switches, thermostats, etc.) and the reference temperature measuring instrument (installed in the calibrator or external reference) are both subjected to test temperatures. The measured values of the reference are compared with the values of the test item. In this way, a statement can be made not only about the function of the test item, but also about the measurement accuracy or the measured value deviation of the test item.

Please note that the specifications regarding radial and axial temperature uniformity given in the respective technical data refer to specific immersion depths and do not necessarily apply to all immersion depths in every case. The temperature range specifications apply at an ambient temperature of +20°C.

The LR-Cal temperature calibration baths have an internal (built-in) reference. If its accuracy is not sufficient, an external reference (without or with its own display) can be used.

The LR-Cal temperature calibration baths (with the exception of the LR-Cal LTC 100/200-F(-PLUS) devices) are each available in two different versions. A basic version, as well as a version "-2I" with integrated measuring inputs for two temperature sensors (Pt 100 or thermocouple), e.g. one external reference sensor and one test item, or two test items. In this version, all three temperatures are displayed simultaneously: the measured value of the reference integrated in the calibrator and the measured values of the two externally connected sensors.

Furthermore, the LR-Cal AQ2sp2 PC software is available as an option for the LR-Cal temperature calibration baths. With this, the calibrator can be completely controlled from the PC via its serial interface, manual or automatic calibration of one or more DUTs, load and lifetime tests, thermostat tests, as well as the creation of calibration certificates.

Synonyms

Temperature calibration baths are also referred to as

  • Calibration bath
  • Micro bath
  • Temperature bath
  • Temperature calibrator
  • Temperature calibration device
  • Temperature calibration bath