LR-Cal PYROS-140-1L
Compact dry block (well) temperature calibrator
-26...+140°C
Description
LR-Cal PYROS 140-1L description
The compact metal block temperature calibrator LR-Cal PYROS 140 1L serves as temperature source and reference instrument in one, for testing and calibration of temperature measuring instruments of all kinds.
- Temperature range -26...+140°C
- 1 dry metal black made from aluminum, 19 mm diameter
- Compact and lightweight
- Power supply 115/240 VAC, 50/60 Hz
- Ramp function
- Thermostat tests
- Various block inserts with different holes for test specimens available
- Particularly proven also on board ships (marine industry)
- Computer interface (RS232, optional with USB converter (accessory)
Specification
LR-Cal PYROS 140-1L specification
| Description: | Data: | |
|---|---|---|
| Tmperature range (at 20°C ambient temp.) |
-26°C...+140°C / -14.8°C...+284°F | |
| Temperature display | Accuracy ±0.25°C ±1 Digit Resolution 0.1° (°C oder °F) |
|
| Stability of regulated temperature | ±0.1°C | |
| Mean heating time (incl. stabilization) | from ambient temperature to +120°C approx. 17 min. | |
| Mean cooling time (incl. stabilization) | from +120°C to ambient temperature approx. 15 min. | |
| Axial temperature uniformity (measured at 40 mm from the bottom) |
at -20°C ±0.1°C at 0°C ±0.05° at 100°C ±0.1°C |
|
| Radial temperature uniformity (measured at 40 mm from the bottom) |
at 100°C ±0.05°C | |
| Metal block depth | 104 mm | |
| Metal block diameter | 19 mm | |
| Metal block insert material | Anticorodal (aluminum-alloy) | |
| Switch test, voltage | On/Off, 12 VDC | |
| Programmable ramp function | 0.1...10°C/min | |
| Automatic calibration possible | on 5 points (via keypad) | |
| Power supply | 115...240 VAC ±10% 50/60 Hz | |
| Power consumption | 80 W | |
| Interface | RS232 (optional with USB converter) | |
| Housing material | Metal | |
| Weight | approx. 5.5 kg | |
| Dimension | 130 x 260 x 280 mm | |
| Order-Code | PYROS-140-1L | |
All stated values valid at ambient temperature +20°C.
Diameter of sensors, used for evaluating above data: 3 mm.
Scope of standard supply
LR-Cal PYROS 140-1L scope of standard supply
- Portable compact dry block temperature calibrator LR-Cal PYROS 140-1L
- Spare fuses
- Cable for power supply
- Connection cables for thermostat tests
- 1 insert mit 4 holes: 3.3 + 4.8 + 6.4 + 6.4 mm diameter
- Insert removal tool
- Factory calibration certificate (performance and accuracy)
- Operating manual DE+EN
Available dry block inserts
LR-Cal PYROS 140-1L available dry block inserts

| Order-Code | Description |
|---|---|
| PYROS-140-1L-INS-0 | Insert sleeve without hole(s), for self-drilling 1 piece already included in the device scope of delivery |
| PYROS-140-1L-INS-4 | Insert with 4 holes: 3.3 + 4.8 + 6.4 + 6.4 mm 1 piece already included in the device scope of delivery |
LR-Cal PYROS 140-1L other accessories
Shoulder bag
Accessory:
Padded shoulder bag
for PYROS devices
Waterproof case
Accessory:
Splashproof case
Protection class IP 65
e.g. for marine applications
Aq2Sp2 software
Accessory:
Windows®-PC software
Control of the calibrator from the PC, manual or automatic calibration of one or more test items, load and endurance tests, thermostat tests (incl. hystersis), generation of calibration certificates
Special RS232 cable
Accessory:
Special RS232 connection cable
RS232/USB converter
Accessory:
Interface converter
RS232 to USB
What is temperature calibration with a metal block temperature calibrator?
The test item (temperature measuring instruments of all types, e.g. dial thermometers, glass thermometers, resistance thermometers, temperature switches, thermostats, etc.) and the reference temperature measuring instrument (installed in the calibrator or external reference) are both subjected to test temperatures. The measured values of the reference are compared with the values of the test item. In this way, a statement can be made not only about the function of the test item, but also about the measurement accuracy or the measured value deviation of the test item.
Please note that the specifications regarding radial and axial temperature uniformity given in the respective technical data refer to specific immersion depths and do not necessarily apply to all immersion depths in every case. The temperature range specifications apply at an ambient temperature of +20°C.
The LR-Cal metal block temperature calibrators have an internal (built-in) reference. If its accuracy is not sufficient, an external reference (without or with its own display) can be used.
The LTC-MP-3I option is available for LR-Cal LTC metal block temperature calibrators (except for versions LTC-DB-0550-60 and LR-Cal LTC-DB-1200-35), with three measurement inputs (2 x for RTD/TC and 1 x for analog signal 4... 20 mA/0...10 V).
The LR-Cal LTC-DB-0550-60 metal block temperature calibrator is available in two versions: standard version and “-2I” version with 2 measuring inputs (for RTD/TC).
This option is not available for the LR-Cal metal block temperature calibrators of the compact PYROS series.
Furthermore, the LR-Cal Aq2Sp2 PC software is available as an option for the LR-Cal metal block temperature calibrators. This allows the calibrator to be completely controlled from the PC via its serial interface, manual or automatic calibration of one or more DUTs, load and life tests, thermostat tests, as well as the generation of calibration certificates.
Synonyms
Metal block temperature calibrators are also referred to as
- Dry block calibrator
- Dry well calibrator
- Calibration furnace
- Temperature calibrator
- Temperature calibration device
- Temperature calibration furnace