Skip to main content

LR-Cal LTC 100-F

LR-Cal LTC 100-F
Portable temperature micro bath
-35...+160°C

LR-Cal LTC 100-F temperature micro bath LR-Cal
  • Portable, operation via touch screen
  • Temperature range -35°C...+160°C
  • Accuracy ±0.1°C, stability ±0.01°C
  • Calibration bath volume 0.7 liter
    (60 mm diameter, 195 mm immersion depth)
  • Option: exchangeable calibration bath inserts (thus easier change of operating liquid for different temperatures)
  • Option: metal block inserts with 4 to 12 holes, blackbody radiator, surface probe

The illustrations also show options and accessories subject to extra charge.

  • Temperature calibration bath LR-Cal LTC 100-F

    LR-Cal LTC 100-F

    Temperature calibration micro bath
    LR-Cal LTC 100-F

  • Temperature calibration micro bath LR-Cal LTC 100-F

    LR-Cal LTC 100-F

    Temperature calibration micro bath
    LR-Cal LTC 100-F

  • Temperature calibration micro bath LR-Cal LTC 100-F

    LR-Cal LTC 100-F

    Temperature calibration micro bath
    LR-Cal LTC 100-F

  • Description

    LR-Cal LTC 100-F description

    The LR-Cal LTC 100-F portable temperature calibration bath serves as a temperature source and reference instrument in one, for testing and calibrating all types of temperature measurement devices. Calibration bath inserts (simplifies silicone oil change) and various metal block inserts are also available.

    • Optimal for calibration of glass thermometers and laboratory thermometers as well as temperature sensors with not exactly cylindrical shape
    • Optional calibration bath inserts simplify (temperature-related) operating liquid changes
    • Metal block inserts with 4 to 12 holes as well as for surface probe and with black body for IR thermometer
    • Data logging and trend graphs
    • Color 4.3" touch screen, very easy operation
    • Calibration bath immersion depth 190 mm, tank diameter 60 mm (0.7 liter volume)
    • Accuracy 0.1°C, temperature stability ±0.01°C, temperature uniformity ±0.05°C
    • Two USB and one Ethernet interface
    • Homogeneous temperature distribution, in calibration bath application by controllable magnetic mixer

    Image:
    Top view of calibration bath opening

    Top view of calibration bath opening

    Image:
    Rear of device

    Rear of device

  • Specification

    LR-Cal LTC 100-F specification

    Temperature range (at +20°C ambient temperature) -35°C...+165°C (-31°F...+329°F)
    (minimum temperature is 55°C (131°F) below ambient; absolute minimum is -35°C (-31°F))
    Temperature indication Accuracy ±0.1°C
    Resolution 0.001°/0.01°/0.1° (°C or °F)
    Stability of the regulated temperature ±0.01°C (±0.02°F)
    Heating 12 minutes from -5°C to +100°C (23°F to 215°F)
    Cooling 34 minutes from +25°C to -25°C (77°F to -13°F)
    Temperature uniformity ±0.05°C (0.09°F)
    Operation fluid Silicone oil AC 10 (not included in standard delivery)
    Tank diameter / insertion depth 60 mm diameter, 190 mm depth
    Power supply 115...230 VAC 50/60 Hz
    Power consumption max. 310 W
    Interfaces 2 x USB, 1 x Ethernet
    Tank material Aluminium
    Tank volume approx. 700 cm³
    Housing material Metal
    Weight approx. 15,2 kgs
    Dimension 280 x 370 x 490 mm

    The stated accuracies are valid at ambient temperature +10...+40°C and are guaranteed for one year.
    Warranty: 3 years warranty against manufacturing defects.

  • Touchscreen screenshots

  • Scope of standard supply

    LR-Cal LTC 100-F scope of standard supply

    • Temperature calibration micro bath LR-Cal LTC 100-F
    • Power supply cable
    • Factory calibration certificate
    • Operating manual DE+EN
  • Available block inserts

  • Options + other accessories

LR-Cal LTC 100-F options + other accessories

  • DKD-T-KAL-TK-6T

    DAkkS calibration certificate

    Code: DKD-T-KAL-TK-6T

    Option:
    DAkkS calibration certificate
    (instead of factory certificate)

  • LTC-F-EXTENS

    2nd. measuring input Pt 100

    Art.Nr.: LTC-F-EXTSENS

    Option:
    Second measuring input channel of the PID controller built into the device, incl. FA-DIN6 connector, for Pt 100 (3-/4-wire).

    With this option, the device can be operated with an external reference sensor.

  • LTC-F-PT100

    Ext. PT 100 reference probe

    Code: LTC-F-PT100

    Accessory:
    External precision reference sensor
    Pt 100 incl. FA-DIN6 socket for direct connection to the instrument (option LTC-F-EXTSENS must be ordered here!).

    Temperature range -50...+300°C
    accuracy ±0,1°C
    probe diameter 4 mm
    Immersion length 300 mm

    Measured values integrated in device certificate: Measuring chain external probe and device display, if ordered together with basic device.

  • LTC-F-DECKEL-05

    Container insulation cover

    Code: LTC-F-DECKEL-05

    Accessory:
    Calibration container lid (for calibration bath insert), for screwing in, made of transparent acrylic.

    Incl. 5 holes for DUTs and a central fixation for the optional external reference sensor LTC-F-PT100 with input LTC-F-EXTSENS.

    This accessory allows convenient fixation of the DUTs and ensures less temperature loss through the vessel opening.

  • LTC-F-KOFFER

    Trolley case

    Code: LTC-F-KOFFER

    Accessory:
    Sturdy trolley case with wheels and extendable handle

  • LTC-F-AC10

    Silicone oil AC 10

    Code: LTC-F-AC10

    Accessory:
    1 liter bottle with calibration medium
    Silicone oil AC 10
    Working range -30...+160°C
    Flash point 170°C
    Viscosity at 25°C: 10 cSt
    Viscosity at 60°C: 6 cSt
    Thermal
    conductivity: 0.140 W/m K
    Heat capacity: 1,5 KJ/kg K
    Specific gravity: 0.94

  • LTC-F-AC20

    Silicone oil AC 20

    Code: LTC-F-AC20

    Accessory:
    1 liter bottle with calibration medium
    Silicone oil AC 20
    Working range -20...+200°C
    Flash point 240°C
    Viscosity at 25°C: 20 cSt
    Viscosity at 60°C: 12 cSt
    Thermal
    conductivity: 0.140 W/m K
    Heat capacity: 1,5 KJ/kg K
    Specific gravity: 0.95

LR-Cal LTC 100-F available block inserts

  • LTC-F-INSERT-FL

    Calibration bath insert

    Code: LTC-F-INSERT-FL

    Accessory:
    Calibration bath insert
    incl. hanging basket, magnetic mixer rod and closing lid.

    Immersion depth 190 mm
    diameter 60 mm
    Volume 0.7 liters

    With additional calibration bath inserts, you simplify the use of the device considerably when you work with different silicone oils (due to temperature): You simply replace the insert instead of emptying and cleaning the bath each time.

  • LTC-F-MB-04

    Dry block insert

    Code: LTC-F-MB-04

    Accessory:
    Metal dry block insert
    with 4 holes
    1x3.5 + 1x6.5 + 1x8.5 + 1x10.5
    mm diameter

  • LTC-F-INSERT-10

    Dry block insert

    Code: LTC-F-INSERT-10

    Accessory:
    Metal dry block insert
    with 10 holes
    2x3.5 + 2x4.5 + 2x6.5 + 2x8.5 + 2x10.5
    mm diameter

  • LTC-F-INSERT-12

    Dry block insert

    Code: LTC-F-INSERT-12

    Accessory:
    Metal dry block insert
    with 12 holes
    3x3.5 + 3x6.5 + 3x8.5 + 3x10.5
    mm diameter

  • LTC-F-INSERT-10S

    Dry block insert

    Code: LTC-F-INSERT-10S

    Accessory:
    Metal dry block insert
    with 12 holes
    2x3.5 + 2x4.5 + 2x5.5 + 2x6.5 + 1x8.5 + 2x9.5 + 1x10.5
    mm diameter

  • LTC-F-INSERT-B

    Dry block insert (blank)

    Code: LTC-F-INSERT-B

    Accessory:
    Metal dry block insert
    without holes
    (for self-drilling)

  • LTC-F-INSERT-OF

    Dry block insert

    Code: LTC-F-INSERT-OF

    Accessory:
    Metal dry block insert
    for temperature surface probes

  • LTC-F-INSERT-BB

    Black Body insert

    Code: LTC-F-INSERT-BB

    Accessory:
    Metal dry block insert
    with Black Body

    for testing, adjustment and calibration of non-contact infrared thermometers

Various images of the touchscreen:

  • Operation via touchscreen LR-Cal LTC 100/200-F

    Bedienung via Touchscreen

  • Operation via touchscreen LR-Cal LTC 100/200-F

    Bedienung via Touchscreen

  • Operation via touchscreen LR-Cal LTC 100/200-F

    Bedienung via Touchscreen

  • Operation via touchscreen LR-Cal LTC 100/200-F

    Bedienung via Touchscreen

  • Operation via touchscreen LR-Cal LTC 100/200-F

    Bedienung via Touchscreen

  • Operation via touchscreen LR-Cal LTC 100/200-F

    Bedienung via Touchscreen

Information about suitable calibration media

Calibration liquids for LR-Cal temperature calibration baths

Basically, temperature calibration baths can be filled with three types of calibration media:

  • Media that are in a liquid state at ambient temperature, e.g. oils, alcohol and water/alcohol mixtures.
      
  • Two-phase media which become liquid at the intended temperature application range of the calibrator. These are usually mixtures of potassium and sodium salts which are powdery at ambient temperature and become liquid at temperatures between 150°C and 500°C. They are used exclusively in calibration baths specially suited for this purpose.
      
  • Other solid substances which under certain circumstances or temperatures reach a state similar to a liquid medium, e.g. sand or aluminum powder with extremely fine grain/granularity.

DRUCK & TEMPERATUR Leitenberger GmbH does not use two-phase media for the calibration bath inserts, although their temperature range is very high.
This is because such media can be very dangerous for the user and even cause explosions.

DRUCK & TEMPERATUR Leitenberger GmbH also does not manufacture calibration bath inserts suitable for use with solid substances, e.g. aluminum powder.
This is because it is not possible to prevent 100% that corresponding powder particles get into the environment during operation of the calibrator. These media are not environmentally compatible.

The calibration media sold by DRUCK & TEMPERATUR Leitenberger GmbH for calibration bath inserts are therefore exclusively silicone oils.

Suitable calibration media for instruments of the LR-Cal LTC 100/200-F(-PLUS) series:

Type of calibration medium (liquid) Possible field of application
*)
Smoke flash point
***)
Silicone oil AC 05 -40...+125°C +42°C
Silicone oil AC 10 -30...+160°C +170°C
Silicone oil AC 20 -20...+200°C +240°C
Silicone oil AC 50 +30...+220°C +280°C
Silicone oilAC 100 +70...+288°C +315°C
*) The "possible range of use" describes the theoretical usability of the medium. However, the viscosity may be unfavorable for practical use as a calibration medium, especially in the lower part of the application range.
***) Above the specified temperatures, the smoke ignites (CAUTION: open fire!).

The calibration media are subject to wear (degeneration), which is greater the more often and longer they have been exposed to high temperatures. Therefore, avoid unnecessarily high temperatures over an unnecessarily long period of time.

Read more …LR-Cal LTC 100-F

  • Hits: 477

LR-Cal PYROS-650

LR-Cal PYROS-650
Compact dry block (well) temperature calibrator
+30...+650°C

LR-Cal PYROS-650 dry block temperature calibrator LR-Cal
  • Portable and compact
    Metal block temperature calibrator
  • Temperature range +30...+650°C
  • Accuracy ±0.5°C, stability ±0.3°C
  • Block: 26 mm diameter
    Insertion depth: 150 mm
  • Entnahme der Einsatzhülse am LR-Cal PYROS-650

    Entnahme der Einsatzhülse am LR-Cal PYROS-650

    Entnahme der Einsatzhülse am
    LR-Cal PYROS-650

  • Schaltertest mit dem LR-Cal PYROS-650

    Schaltertest mit dem LR-Cal PYROS-650

    Temperaturschalter-Test mit dem
    LR-Cal PYROS-650

  • Description

    LR-Cal PYROS-650 description

    The compact metal block temperature calibrator LR-Cal PYROS 650 serves as temperature source and reference instrument in one, for testing and calibrating temperature measuring instruments of all kinds.

    • Temperature range +30...+650°C
    • Type approval by DNV-GL (No. TAA00002CX)
    • 1 dry metal block 26 mm diameter
    • Compact and lightweight
    • Power supply 115 VAC or 230 VAC, switchable
    • Ramp function
    • Thermostat tests
    • Various block inserts with different holes for test specimens available
    • Particularly proven also on board ships (marine industry)
    • Computer interface (RS232, interface converter RS232-USB available as accessory)
  • Specification

    LR-Cal PYROS-650 specification

    Temperature range
    (at 20°C ambient temp.)
    +35°C...+650°C
    Temperature display Accuracy ±0.5°C ±1 Digit
    Resolution 0.1° (°C or °F)
    Stability of regulated temperature ±0.3°C
    Heating from +50°C to +650°C: 35 min.
    Cooling from +650°C to +100°C: 60 min.
    Temperature uniformity at +250°C
    radial ±0.22°C (at 40 mm)
    axial ±0.13°C
    Metal block depth 150 mm usable insertion length
    Metal block diameter 26 mm
    Power supply 115 + 230 VAC switchable
    Power consumption 600 W
    Interface RS 232
    Case material Metal (steel)
    Weight approx. 6 kg
    Dimension 130 x 260 x 280 mm
  • Scope of standard supply

    LR-Cal PYROS-650 scope of standard supply

    • Portable compact dry block temperature calibrator LR-Cal PYROS-650
    • Spare fuses
    • Cable for power supply
    • Connection cables for thermostat tests
    • 1 insert with 4 holes (3.2 + 5.0 + 7.0 + 10.5 mm)
    • Removal tool for changing insert sleeves
    • Factory calibration certificate (performance and accuracy)
    • Operating manual DE+EN
  • Available dry block inserts

    LR-Cal PYROS-650 available dry block inserts

    Code Description
    PYROS-650-INS-0 Insert sleeve without hole(s), for self-drilling
    PYROS-650-INS-4 Insert with 4 holes: 3.2 + 5.0 + 7.0 + 10.5 mm diameter
    1 piece already included in the device scope of delivery
    PYROS-650-INS-3S Insert with 3 holes: 4.5 + 6.5 + 10.5 mm diameter
    PYROS-650-INS-2 Insert with 2 holes: 6.5 + 12.7 mm diameter
    PYROS-650-INS-2S1 Insert with 2 holes: 6.5 + 13.5 mm diameter
    PYROS-650-INS-1 Insert with 1 hole: 15.7 mm diameter
    PYROS-650-INS-1S Insert with 1 hole: 17.5 mm diameter
    PYROS-650-INS-1S1 Insert with 1 hole: 20.0 mm diameter
  • Other accessories

LR-Cal PYROS-140-2L other accessories

  • PYROS-TASCHE

    Shoulder bag

    Code: PYROS-TASCHE

    Accessory:
    Padded shoulder bag
    for PYROS devices

  • PYROS-KOFFER

    Waterproof case

    Code: PYROS-KOFFER

    Accessory:
    Splashproof case
    Protection class IP 65
    e.g. for marine applications

  • RS232-USB-KONV

    RS232/USB- converter

    Code: RS232-USB-KONV

    Accessory:
    Interface converter
    RS232 to USB

Read more …LR-Cal PYROS-650

  • Hits: 550

LR-Cal PYROS-375

LR-Cal PYROS-375
Compact dry block (well) temperature calibrator
+30...+375°C

LR-Cal PYROS-375 dry block temperature calibrator LR-Cal
  • Portable and compact
    dry block temperature calibrator
  • Temperature range +30...+375°C
  • Accuracy ±0.35°C, stability ±0.1°C
  • Block: 26 mm diameter
    Insertion depth: 150 mm
  • Insert removal with LR-Cal PYROS-375

    Entnahme der Einsatzhülse am LR-Cal PYROS-375

    Insert removal with
    LR-Cal PYROS-375

  • Thermostat test with LR-Cal PYROS-375

    Thermostat test with LR-Cal PYROS-375

    Thermostat test with
    LR-Cal PYROS-375

  • Description

    LR-Cal PYROS-375 description

    The compact metal block temperature calibrator LR-Cal PYROS 375 serves as temperature source and reference instrument in one, for testing and calibrating temperature measuring instruments of all kinds.

    • Temperature range +30...+375°C
    • Type approval by DNV-GL (No. TAA00002CX)
    • 1 dry metal block, 26 mm diameter
    • Compact and lightweight
    • Power supply 115 VAC or 230 VAC, switchable
    • Ramp function
    • Thermostat tests
    • Various block inserts with different holes for test specimens available
    • Particularly proven also on board ships (marine industry)
    • Computer interface (RS232, interface converter RS232-USB available as accessory)
  • Specification

    LR-Cal PYROS-375 specification

    Temperature range
    (at 20°C ambient temperature)
    +30°C...+375°C
    Temperature display Accuracy ±0.35°C
    Resolution 0.1° (°C or °F)
    Stabilty of regulated temperature ±0.1°C
    Heating from +30°C to +375°C: 20 min.
    Cooling from +375°C to +40°C: 40 min.
    Temperature uniformity at +50°C
    radial ±0.1°C (at 40 mm insertion depth)
    axial ±0.1°C (at 40 mm insertion depth)
    Dry block depth 150 mm usable insertion length
    Dry block diameter 26 mm
    Power supply 115 + 230 VAC switchable
    Power consumption 600 W
    Interface RS 232
    Case material Metal (steel)
    Weight approx. 5.4 kg
    Dimension 130 x 260 x 280 mm
  • Scope of standard supply

    LR-Cal PYROS-375 scope of standard supply

    • Portable compact dry block temperature calibrator LR-Cal PYROS-375
    • Spare fuses
    • Cable for power supply
    • Connection cables for thermostat tests
    • 1 insert with 4 holes (3.2 + 4.8 + 6.4 + 11.1 mm)
    • Removal tool for changing insert sleeves
    • Factory calibration certificate (performance and accuracy)
    • Operating manual DE+EN
  • Available dry block inserts

    LR-Cal PYROS-375 available dry block inserts

    Code Description
    PYROS-375-INS-0 Insert sleeve without hole(s), for self-drilling
    PYROS-375-INS-4 Insert with 4 holes: 3.2 + 4.8 + 6.4 + 11.1 mm diameter
    1 piece already included in the device scope of delivery
    PYROS-375-INS-2 Insert with 2 holes: 6.4 + 12.7 mm diameter
    PYROS-375-INSKW-2 Insert with 2 holes according to customer's request, from 3 to 11 mm diameter
    (please specify required diameter in order, design as far as technically feasible)
    PYROS-375-INS-3 Insert with 3 holes according to customer's request, from 3 to 11 mm diameter
    (please specify required diameter in order, design as far as technically feasible)
    PYROS-375-INS-5 Insert with 5 holes according to customer's request, from 3 to 11 mm diameter
    (please specify required diameter in order, design as far as technically feasible)
  • Other accessories

LR-Cal PYROS-140-2L other accessories

  • PYROS-TASCHE

    Shoulder bag

    Code: PYROS-TASCHE

    Accessory:
    Padded shoulder bag
    for PYROS devices

  • PYROS-KOFFER

    Waterproof case

    Code: PYROS-KOFFER

    Accessory:
    Splashproof case
    Protection class IP 65
    e.g. for marine applications

  • RS232-USB-KONV

    RS232/USB converter

    Code: RS232-USB-KONV

    Accessory:
    Interface converter
    RS232 to USB

Read more …LR-Cal PYROS-375

  • Hits: 389

LR-Cal PYROS-140-1L

LR-Cal PYROS-140-1L
Compact dry block (well) temperature calibrator
-24...+140°C

LR-Cal PYROS-140-2L dry block temperature calibrator LR-Cal
  • Portable and compact
    dry block temperature calibrator
  • Temperature range -24...+140°C
  • Accuracy ±0.25°C, stability ±0.05°C
  • Block: 19 mm diameter
    Insertion depth: 104 mm
  • Insert removal with LR-Cal PYROS-140-1L

    Entnahme der Einsatzhülse am LR-Cal PYROS-140-1L

    Insert removal with
    LR-Cal PYROS-140-1L

  • Thermostat test with LR-Cal PYROS-140-1L

    Schaltertest mit dem LR-Cal PYROS-140-1L

    Thermostat test with
    LR-Cal PYROS-140-1L

  • Description

    LR-Cal PYROS-140-1L description

    The compact metal block temperature calibrator LR-Cal PYROS 140-1L serves as temperature source and reference instrument in one, for testing and calibration of temperature measuring instruments of all kinds.

    • Temperature range -24...+140°C
    • 1 dry metal black made from aluminum, 19 mm diameter
    • Compact and lightweight
    • Power supply 110...230 VAC (universal)
    • Ramp function
    • Thermostat tests
    • Various block inserts with different holes for test specimens available
    • Particularly proven also on board ships (marine industry)
    • Computer-Schnittstelle (RS232, Schnittstellenkonverter RS232-USB als Zubehör lieferbar)
  • Specification

    LR-Cal PYROS-140-1L specification

    Tmperature range
    (at 20°C ambient temp.)
    -24°C...+140°C
    Temperature display Accuracy ±0.25°C ±1 Digit
    Resolution 0.1° (°C oder °F)
    Stability of regulated temperature ±0.1°C
    Heating from +20°C to +120°C: 20 min.
    Cooling from +20°C to -20°C: 17 min.
    Temperature uniformity at 0°C
    radial ±0.1°C (at 40 mm insertion depth)
    axial ±0.12°C
    Metal block depth 104 mm
    Metal block diameter 19 mm
    Power supply 100...230 VAC ±10%
    Power consumption 80 W
    Interface no
    Housing material Metal (steel)
    Weight approx. 4.9 kg
    Dimension 130 x 260 x 280 mm
  • Scope of standard supply

    LR-Cal PYROS-140-1L scope of standard supply

    • Portable compact dry block temperature calibrator LR-Cal PYROS-140-1L
    • Spare fuses
    • Cable for power supply
    • Connection cables for thermostat tests
    • 1 insert mit 4 holes: 3.3 + 4.8 + 6.4 + 6.4 mm diameter
    • Insert removal tool
    • Factory calibration certificate (performance and accuracy)
    • Operating manual DE+EN
  • Available dry block inserts

    LR-Cal PYROS-140-1L available dry block inserts

    Code Description
    PYROS-140-1L-INS-0 Insert sleeve without hole(s), for self-drilling
    PYROS-140-1L-INS-4 Insert with 4 holes: 3.3 + 4.8 + 6.4 + 6.4 mm
    1 piece already included in the device scope of delivery
  • Other accessories

LR-Cal PYROS-140-1L other accessories

  • PYROS-TASCHE

    Shoulder bag

    Code: PYROS-TASCHE

    Accessory:
    Padded shoulder bag
    for PYROS devices

  • PYROS-KOFFER

    Waterproof case

    Code: PYROS-KOFFER

    Accessory:
    Splashproof case
    Protection class IP 65
    e.g. for marine applications

  • RS232-USB-KONV

    RS232/USB converter

    Code: RS232-USB-KONV

    Accessory:
    Interface converter
    RS232 to USB

Read more …LR-Cal PYROS-140-1L

  • Hits: 388

LR-Cal PYROS-140-2L

LR-Cal PYROS-140-2L
Compact dry block (well) temperature calibrator
-24...+140°C

LR-Cal PYROS-140-2L dry block temperature calibrator LR-Cal
  • Portable and compact
    dry block temperature calibrator
  • Temperature range -24...+140°C
  • Accuracy ±0,25°C, stability ±0,05°C
  • Block: 2 x 13 mm diameter
    Insertion depth: 104 mm
  • Removal of the insert with LR-Cal PYROS-140-2L

    Entnahme der Einsatzhülse am LR-Cal PYROS-140-2L

    Removal of the insert with
    LR-Cal PYROS-140-2L

  • Thermostat test with LR-Cal PYROS-140-2L

    Schaltertest mit dem LR-Cal PYROS-140-2L

    Thermostat test with
    LR-Cal PYROS-140-2L

  • Description

    LR-Cal PYROS-140-2L description

    The compact metal block temperature calibrator LR-Cal PYROS 140-2L serves as temperature source and reference instrument in one, for testing and calibration of temperature measuring instruments of all kinds.

    • Temperature range -24...+140°C
    • 2 metal blocks made from copper, each 13 mm diameter
    • Compact and lightweight
    • Power supply 110...230 VAC (universal)
    • Ramp function
    • Thermostat test
    • Various block inserts with different drillings for test items available
    • Particularly proven also on board ships (marine industry)
    • Computer interface (RS232, interface converter RS232-USB available as accessory)
  • Specification

    LR-Cal PYROS-140-2L specification

    Tmperature range
    (at 20°C ambient temp.)
    -24°C...+140°C
    Temperature display Accuracy ±0.25°C ±1 Digit
    Resolution 0.1° (°C oder °F)
    Stability of regulated temperature ±0.1°C
    Heating from +20°C to +120°C: 20 min.
    Cooling from +20°C to -20°C: 17 min.
    Temperature uniformity at -20°C, from hole to hole
    radial ±0.02°C (at 40 mm insertion depth)
    axial ±0.05°C
    Metal block depth 104 mm
    Metal block diameter 2 x 13 mm (distance 20 mm)
    Power supply 100...230 VAC ±10%
    Power consumption 80 W
    Interface no
    Housing material Metal (steel)
    Weight approx. 4.9 kg
    Dimension 130 x 260 x 280 mm
  • Scope of standard supply

    LR-Cal PYROS-140-2L scope of standard supply

    • Portable compact dry block temperature calibrator LR-Cal PYROS 140-2L
    • Spare fuses
    • Cable for power supply
    • Connection cables for thermostat tests
    • 1 insert 1 hole 4.8 mm diameter
    • 1 insert 1 hole 6.4 mm diameters
    • Removal tool for changing insert sleeves
    • Factory calibration certificate (performance and accuracy)
    • Operating manual DE+EN
  • Available dry block inserts

    LR-Cal PYROS-140-2L available dry block inserts

    Code Description
    PYROS-140-2L-INS-0 Insert sleeve without hole(s), for self-drilling
    PYROS-140-2L-INS-032 Insert with 1 hole 3.2 mm (1/8")
    PYROS-140-2L-INS-040 Insert with 1 hole 4.0 mm (5/32")
    PYROS-140-2L-INS-048 Insert with 1 hole 4.8 mm (3/16")
    1 piece already included in the device scope of delivery
    PYROS-140-2L-INS-064 Insert with 1 hole 6.4 mm (1/4")
    1 piece already included in the device scope of delivery
    PYROS-140-2L-INS-079 Insert with 1 hole 7.9 mm (5/16")
    PYROS-140-2L-INS-095 Insert with 1 hole 9.5 mm (3/8")
    PYROS-140-2L-INS-111 Insert with 1 hole 11.1 mm (7/16")
    PYROS-140-2L-INS-KW Insert with 1 hole according to customer requirements
    (specify desired diameter when ordering)
  • Other accessories

LR-Cal PYROS-140-2L other accessories

  • PYROS-TASCHE

    Shoulder bag

    Code: PYROS-TASCHE

    Accessory:
    Padded shoulder bag
    for PYROS devices

  • PYROS-KOFFER

    Waterproof case

    Code: PYROS-KOFFER

    Accessory:
    Splashproof case
    Protection class IP 65
    e.g. for marine applications

  • RS232-USB-KONV

    RS232/USB converter

    Code: RS232-USB-KONV

    Accessory:
    Interface converter
    RS232 to USB

Read more …LR-Cal PYROS-140-2L

  • Hits: 403