Portable Temperature Calibration Micro Bath
Model LR-Cal FLUID 200
Temperature range: ambient temperature...+200°C
The LR-Cal FLUID 200 is a portable stirred liquid bath (temperature calibrator). The instrument is suitable for calibrating temperature sensors and thermometers of all sizes, diameters and shapes, without the need of specifically drilled blocks. The calibration baths are perfect for checking and calibration of glass thermometers.
- Large calibration volume 500 cm³
- Auto Ramp function, programmable
- Auto Step function, programmable
- Computer aided calibration via computer interface and optional PC software LR-Cal AQ2sp
- Switch test functionality
- Optional dry block and black body inserts available
Instrument Versions
LR-Cal FLUID 200 Instrument versions
The portable liquid bath LR-Cal FLUID 200 is available in two versions:
Version LR-Cal FLUID 200
Standard version
Order-Code: 508.0.000.0200.0
Without measuring inputs
Version LR-Cal FLUID 200-2I
Version with 2 measuring inputs
Order-Code: 508.0.111.0200.0

Both measuring inputs are suitable for resistance thermometer Pt 100 (2-, 3- or 4-wire) or Pt 1000, as well as for thermocouples (incl. cold junction compensation) types B, E, J, K, N, R, S and T.
The signal of connected probes can be displayed additionally in instruments display.
Extended scope of standard delivery:
Electr. cables, tools (plugs) for electr. connections
Accuracy (maximal deviation) at both measuring inputs at version "-2I": |
Pt 100 or Pt 1000 |
at -40°C: |
±0.09°C |
at 0°C: |
±0.08°C |
at +150°C: |
±0,11°C |
at +300°C: |
±0.14°C |
Thermocouple type B |
at +950°C: |
±0.97°C |
at +1050°C: |
±1.03°C |
at +1200°C: |
±1.12°C |
|
|
Thermocouple type E |
at -40°C: |
±0.42°C |
at 0°C: |
±0.40°C |
at +350°C: |
±0.61°C |
|
|
Thermocouple type J |
at +200°C: |
±0.52°C |
at +450°C: |
±0.67°C |
at +700°C: |
±0.82°C |
|
|
Thermocouples types K, N, R und S |
at +400°C: |
±0.64°C |
at +700°C: |
±0.82°C |
at +1000°C: |
±1.00°C |
|
|
Thermocouple typ T |
at -40°C: |
±0.42°C |
at 0°C: |
±0.40°C |
at +350°C: |
±0.61°C |
|
|
Specification
LR-Cal FLUID 200 Specifikation
Temperature range |
ambient temperature...+200°C |
Temperature indication |
Accuracy ±0.15°C Resolution 0.01°/0.1° (°C oder °F) |
Stability of regulated temperature |
±0.02°C at 50°C |
Heating from ambient temperature to 140°C, incl. stabilization |
approx. 25 minutes |
Cooling from 140°C to ambient temperature, incl. stabilization |
approx. 70 minutes |
Uniformity of temperature |
radial: ±0.6°C at 150°C and 40 mm depth; axial: ±0.01°C at 140°C |
Calibration liquid |
<80°C: water <125°C: silicone oil 200C5 <220°C: silicone oil 47V100 |
Liquid reservoir |
Usable reservoir depth 170 mm x container opening diameter 54 mm |
Power supply |
230 VAC (optional 115 VAC) |
Power consumption |
500 VA |
Interface |
RS232 |
Reservoir material |
aluminium |
Reservoir volume |
approx. 500 cm³ |
Housing material |
metal |
Weight |
approx. 8.3 kg |
Dimension |
160 x 360 x 350 mm |
Scope of Delivery + Accessories
LR-Cal FLUID 200 Scope of Delivery + Accessories

Standard scope of delivery:
- Portable Temperature Calibration Bath LR-Cal FLUID 200 resp. LR-Cal FLUID 200-2I
- Fuse kit
- Power lead
- Set of leads for testing thermostats / switches
- Closing lead
- Bottle with 500 cm³ silicone oil 47V20
- Support to fix glass thermometers
- Fluid empty system
- Soft case with pocket and shoulder trap
- Only for version LR-Cal FLUID 200-2I:
Set of leads (red/black) and threaded terminals for both inputs
Optional Accessories:
Order-Code |
Description |
Picture |
REF-T-SENSOR-PT |
External precision reference probe Pt 100 Range -100...+670°C, TK: 0,003850 1/K; Stability <40 mK, Diameter 6,35 mm, Length 450 mm; Bulb made in Inconel 4-wire connection; incl. 2 m PTFE-cable, isolated and zinn plated |
DKD-T-KAL-PT |
for reference probe: DKD-/DAkkS Certificate of Calibration |
RTAB-T-KAL-PT |
for reference probe: calculation of constants |
RTAB2-T-KAL-PT |
alternatively calculation of constants including table of values |
FLUID200-ER |
Extension tube to increase the insertion depth Total depth 250 mm, usable depth 230 mm, min. temp. -9°C. If used with silicone oil 47V20: Working range 90...+200°C, horizontal, uniformity of temperature ±0.2°C (measured 50 mm from bottom); Vertical temperature uniformity ±0.1°C, measured 0...150 mm from bottom |
 |
FLUID200-KS |
Cooling system (needs external fresh water supply) made in stainless steel, to shorten the cooling time. |
 |
FLUID-INS-9 FLUID-INS-0 |
Dry Block Kit Temperature range -10...+125°C. Block made in aluminium, 60 mm diameter, usable depth 170 mm, stability ±0.04°C, with 9 drillings oder blank |
 |
BB-INSERT-01-FLUID |
Black Body Kit for calibration of non-contact infrared thermometers. With high emission grade. Insert with interal grafit plating. Including precision reference probe Pt 100 (4-wire) |

|
599.0.000.0003.0 |
PC-Software LR-Cal AQ2sp incl. RS232-interface lead Temperatur sensor calibration: Automatic calibration routine for all type of temperature sensors with advanced features such reference sensor stabilization, time-calibration data are automatically populated and stored for printing report. This procedure can also be ran in manual mode to allow the operator to manually enter the data. This is particular useful when calibrating temperature device such as digital thermometer or analogue thermometers. Stress test: Simply set MAX and MIN value and the software will run an automatic stress test on single sensor or a batch. Advance thermostat calibration: Simply set the open and close temperature limits, type of thermostat, typ of test and the software will automatically run the test. |
 |
Read this information about calibration fluids...