LR-Cal SOLAR-1200
Dry block temperature calibrator
+200°C...+1200°C
Description
LR-Cal SOLAR-1200 description
The LR-Cal SOLAR-1200 metal block temperature calibrator serves as a temperature source and reference instrument in one, for testing and calibrating all types of temperature measuring instruments.
- Temperature range +200°C to +1200°C
- Ramp function
- Thermostat tests
- Computer-controlled calibrations via computer interface (PC software optionally available)
- Various dry block inserts available with different holes for test specimens
- Incl. factory certificate of accuracy, stability and performance
- Computer interface (RS232, interface converter to USB available as accessory)
Specification
LR-Cal SOLAR-1200 specification
Temperature range | +200°C...+1200°C | |
Temperature indication | Accuracy ±3°C Resolution 0,1° (°C or °F or K) |
|
Stability of regulated temperature | ±0.3°C (at 1000°C) | |
Heating | max. 15°C per minute | |
Cooling | max. 7°C per minute | |
Temperature uniformity | at 1000°C: radial ±2°C axial ±03°C |
|
Block depth | 160 mm | |
Block diameter | 35 mm (block made in ceramic) | |
Power supply | 230 VAC | |
Power consumption | 700 VA | |
Interface | RS232 (optional RS232-USB converter available) | |
Housing material | Metal | |
Weight | approx. 10.5 kg | |
Dimension | 350 x 160 x 390 mm | |
Order-Code | SOLAR-1200 |
Scope of standard supply
LR-Cal SOLAR-1200 scope of standard supply
- Portable dry block temperature calibrator LR-Cal SOLAR-1200
- Spare fuses
- Cable for power supply
- Connection cable for thermostat tests
- Removing tool to change dry block insert
- Factory certificate (accuracy, stability, performance)
- Operating manual EN
Available dry block inserts
LR-Cal SOLAR-1200 available dry block inserts
Order-Code | Description |
SOLAR-K-INS-04S | Ceramic dry block insert with 4 holes: 4.8 + 6.4 + 9.5 + 12.8 mm diameter. (included in the scope of delivery of the device) |
SOLAR-D-INS-04 | Insulating cover with matching holes |
SOLAR-I-INS-04 | Dry block insert made of Inconel with 4 holes: 4.8 + 6.4 + 9.5 + 12.8 mm diameter |
SOLAR-D-INS-04 | Insulating cover with matching holes |
SOLAR-INS-SB | Inconel dry block insert without holes |
511.0.999.0007.0 | Insulating cover without holes |
SOLAR-B-045-060 | Surcharge for SOLAR-INS-SB: 1 hole each according to customer requirements (diameter 4.5 to 6 mm, if feasible) |
SOLAR-B-060-160 | Surcharge for SOLAR-INS-SB: 1 hole each according to customer requirements (diameter 6 to 16 mm, if feasible) |
SOLAR-B-160-260 | Surcharge for SOLAR-INS-SB: 1 hole each according to customer requirements (diameter 16 to 26 mm, if feasible) |
SOLAR-ISO-KW | Surcharge for 511.0.999.0007.0: Drill holes in insulating cover, with adapted drill holes |
LR-Cal SOLAR-1200 other accessories + spare parts
DAkkS certification
Option:
DAkkS certification for the measuring chain consisting of display of the calibrator and internal reference sensor at 6 measuring points
Trolley suitcase
Accessory:
Case with molded foam inserts
for LR-Cal SOLAR-1200
With extendable handle and wheels
Case
Accessory:
Aluminum case with molded foam inserts
for LR-Cal SOLAR-1200
400 x 300 x 500 mm
Windows-PC software
Accessory:
Windows-PC software AQ2Sp2
Download version
incl. RS232 connection cable
RS232-USB converter
Accessory:
Interface converter
RS232 to USB
The test item (temperature measuring instruments of all types, e.g. dial thermometers, resistance thermometers, temperature switches, thermostats, etc.) and the reference temperature measuring instrument (installed in the calibrator or external reference) are both subjected to test temperatures. The measured values of the reference are compared with the values of the test item. In this way, a statement can be made not only about the function of the test item, but also about the measurement accuracy or the measured value deviation of the test item.
Please note that the specifications regarding radial and axial temperature uniformity given in the respective technical data refer to specific immersion depths and do not necessarily apply to all immersion depths in every case. The temperature range specifications apply at an ambient temperature of +20°C.
The LR-Cal metal dry block temperature calibrators have an internal (built-in) reference. If its accuracy is not sufficient, an external reference (without or with its own display) can be used.
Furthermore, the LR-Cal AQ2sp2 PC software is available as an accessory for the LR-Cal metal block temperature calibrators. Herewith the calibrator can be controlled completely from the PC (if necessary with optional RS232/USB converter) via its serial interface, manual or automatic calibration of one or more DUTs, load and lifetime tests, thermostat tests, as well as the creation of calibration certificates.
Synonyms
Metal dry block temperature calibrators are also referred to as
- Dry-well calibrator
- Temperature dry-well calibrator
- Dry block calibrator
- Temperature calibrator
- Temperature calibration device
- Temperature calibration oven