DRUCK & TEMPERATUR Leitenberger GmbH - GERMANY

DRUCK & TEMPERATUR  LEITENBERGER GMBH
Druck- und Temperatur - Mess-, Kalibrier- und  Registriergeräte
Füllstandsonden und -Schalter, Datenlogger

HOME Downloads Neues News E-Mail


Impressum
Kalibrier-Forum
Messen+Ausstellungen
Unsere Produkte:
1. Druckmessgeräte: Manometer, Druckmessumformer, Druckmittler, Digitalmanometer, usw. DruckmessgeräteDruckmessgeräteDruckmessgeräte: Manometer, Druckmessumformer, Druckmittler, usw.
2. DruckkalibriergeräteDruckkalibriergeräteDruckkalibriergeräte
3. TemperaturmessgeräteTemperaturmessgeräteTemperaturmessgeräte
4. TemperaturkalibratorenTemperaturkalibratoren
5.
Füllstand
• Füllstand
6. MessdatenerfassungRegistriergeräteRegistriergeräte - Datenlogger - Opus 10 - Thermohygrographen
7. Sonstige GeräteSonstige Produkte
Unser Service:
Downloads

Datenblätter anfordern

Unsere
Schwesterfirmen:
AUTOTESTGERÄTE
Leitenberger GmbH

LEITENBERGER
Mess- u. Regeltechnik GmbH

HOME > 2: Pressure Calibrators > 2.7: Deadweight Tester > LDW 1000
Deadweight Tester LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany LDW 1000
Accuracy ±0.025% of measured value
2
LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany
Deadweight Tester
Type
LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany LDW 1000
Pressure Balance
Primary Standard for Pressure

Datasheet

Operating Manual

Table of mass loads:
see Operating Manual

LDW 1000 - Deadweight Tester / Pressure Balance
  • Ranges from 0.2 bar to 1000 bar, hydraulic operated
    2.9 psi to 15000 psi
  • Accuracy (total uncertainty of measurement) ±0.025% of measured value
  • Self-sustaining complete system, also suitable for on-site measurements / calibrations
  • Options: DKD Certificate of Calibration, Intelligent Calibration Module LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany IKM for easy Transmitter calibration and automatic calculated corrections
Deadweight Tester (Pressure Balances) are the most accurate instruments for the calibration of electronic or mechanical pressure measuring instruments. The direct measurement of pressure, according to its definition as a quotient of force and area, and the use of high-quality materials result in small uncertainties of measurement and an excellent long-term stability of five years. For these reasons, deadweight testers have already been used in calibration laboratories of industry, national institutes and research labs for many years.

Due to the integrated pressure generation and the purely mechanical measurement principle, the LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany LDW 1000 deadweight testers are ideally suited for on-site use as well as service and maintenance purposes.

The high-quality sensitive piston/cylinder-units are well protected in a special housing. The core of the LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany LDW 1000 is a piston/cylinder system of tungsten carbide. Besides this high-quality material, which primarily stands out for its small temperature coefficient, the workmanship of the system is a measure of the final accuracy of the pressure balance. Several refinement processes ensure a high-quality and even surface with small graps of only a few micrometer.

In order to generate the individual test points, the piston/cylinder system is weighted with mass-loads, which are also calibrated and specially adapted to the respective application. The pressure is set via an integrated spindle pump. For fine adjustment an adjustable volume the system is equipped with a volume variator valve. The weight applied is proportional to the desired pressure and provided by using optimally graduated weights. As soon as the measuring system reaches quilibrium, there is a balance of forces between pressure and wheel weights. Due to the excellent quality of the system this pressure remains stable over several minutes, so that for instance adjustments of your device under test can be carried out without any problems.
 

Intelligent Calibration Module LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany IKM

Datasheet
Operating Manual
Especially when highly accurate measuring values with uncertainties of measurement of less than 0.025% are required, complicated mathematics calculations and corrections used to be necessary.

Intelligent Calibration Module IKM

With this optional addition to the system all critical ambient parameters are registered and automatically corrected. Furthermore, a calibrator function for pressure transmitters is integrated, so that a voltage can be supplied to the sensor and the sensors signals can be measured without any problem.

More optional Accessories
  • Set of trim-masses for generating intermediate values (weights 1 mg to 50 g)
  • Oxytester (Purifier) for measuring instruments where the filling medium should not come into contact with the deadweight tester
  • Dirt trap for test objects that are very dirty in order to avoid the penetration of dirt particles into the deadweight tester
  • Set of adapters in a tool case with 5 most commonly used threaded adapters and a spanner (flats 32 and flats 14)
  • Cleaning Kit "CPB5000-HY-RS" for hydraulic pistons

The mass set is supplied without wooden case. The masses can be placed on the deadweight tester's base plate (see image on the top of this page). At range 1000 bar / 15000 psi a mass set extension (additional masses) are supplied in a wooden case.

Included in Standard Supply

  • Basement and spirit level, adjustable feet.
  • Spindle pump and volume adjustment valve
  • Clamp for specimens
  • One piston/cylinder system
  • Set of stainless steel weights

Technical Data:

Measuring
Range bar
Measuring
Range psi
0.2 ... 60 2.9 ... 1,000
1 ... 250 14.5 ... 5,000
2 ... 600 29 ... 10,000
2 ... 1000 29 ... 15,000

Accuracy (uncertainty):
±0.025% of measured value (%RD). The accuracy is charachterised by the deviation span, which is the sum of the systematic error and the uncertainties of measurement. Longterm stability is not taken into account. Please note that corrections might be required if the instrument is used without the optional Intelligent Calibration Module - see operating manual.


Recommended accessory:

Hand Suction Pump HAP 02

Datasheet

for suction of fluids, e.g. oil, water, break fluid, etc.

Perfect for the suction of the operation fluid of deadweight tester (e.g. before transport etc.).

HAP 02 Handabsaugpumpe zum Entleeren z.B. von Vergleichsprüfpumpen

Other Deadweight Tester models:

  • LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany CPB5000:
    Deadweight Tester Accuracy up to ±0.008% of measure value
    Pneumatic and Hydraulic models
      
  • LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany CPB5000-HP:
    High Pressure Deadweight tester, up to 4000 bar / 60000 psi
      
  • LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany CPB5000-DP:
    Differential Pressure Deadweight Tester

LR-Cal - Leitenberger Kalibriersysteme. Eine Marke von DRUCK & TEMPERATUR Leitenberger GmbH - Germany  

HOME > 2: Pressure Calibrators > 2.7: Deadweight Tester > LDW 1000


Imprint

Fairs+Exhibitions

Our Products:
1. DruckmessgerätePressure InstrumentsPressure Instruments
2. DruckkalibriergerätePressure CalibratorsPressure Calibrator
3. TemperaturmessgeräteThermometerThermometer
4. Temp. CalibratorsTemperature Calibrators
5.
Level / Niveau
• Level / Niveau
6. MessdatenerfassungData LoggerData Logger, Thermohygrograph, OPUS 10
7. Sonstige GeräteOther Products
Our Service:
Downloads

Order Datasheets

Our
Sister Companies:
AUTOTESTGERÄTE
Leitenberger GmbH

LEITENBERGER
Mess- u. Regeltechnik GmbH

 | Copyright © AGENTUR GERD BROGLIE • All rights reserved • Alle Rechte vorbehalten.   

Service DEUTSCHLAND: Service INTERNATIONAL:
• Datenblätter per Anforderungsformular anfordern
• Preisanfrage per E-Mail senden
• Distributoren: Preisliste downloaden
• order gratis datasheets with this formular
• ask for quotation by E-Mail

• distributors: download pricelist

Leitenberger24.de Online-Shop
Messgeräte, Kalibriergeräte, Prüfgeräte günstig kaufen.

DRUCK & TEMPERATUR Leitenberger GmbH   
Bahnhofstr. 33 • D-72138 Kirchentellinsfurt • Tel. +49 - 7121-90920-0 • Fax +49 - 7121-90920-99 
  
www.druck-temperatur.de