Digital Panel Indicator Serie 211 |
 |
Digital Panel Indicator
Type 211
4 digits,
universal input,
48 x 96 mm

Data Sheet
Standard:
- Transmitter and Transducer supply
24 VDC (isolated) for 2-wire transmitter (4-20 mA loop)
10 VDC (regulated), 50 mA
- One relay fitted as standard
- 4-digit LED display (red)
- Front panel protection IP 65
- 110 mm deep
|
 |
|
Type 211 - with hidden
configuration buttons
|
| |
 |
|
Type 211 - with visible
configuration buttons
|
|
- Panel mounting 1/8 DIN size (48 x 96 mm)
- Two hidden configuration buttons behind the front
panel
- Power supply 90..265 VAC (50/60 Hz)
- Easy configuration using concealed buttons,
menu-driven
- Windows software by Download availabel for
configuration
(special adapter lead can be provided to connect to RS232 interface of
a computer system)
Options:
- Up to three alarm relais (two additional relais)
- LED in green color
- Five visible configuration bottons on front panel
Herewith following additional functions are included:
Tare, Zero, Min-, Max
- Analogue output (isolated)
- Power supply 10...32 VDC / VAC
- Adapter lead Type 211 to RS232-interface (PC/Laptop)
Technical Data:
|
Display: |
LED red (optional: green), 14.2 mm high
4 digits (-1999 to +9999)
Update rate: 2 per second |
|
A/D-Converter: |
Dual slope integrating with auto zero, conversion rate: 100 ms,
Common mode rejection > 150 dB |
|
Housing: |
Front panel protection IP 65, 48 x 96 mm, panel cutout 45 x 93 mm,
weight 0.4 kg |
|
Environmental: |
Temperature 10-50°C operating, -10/+70°C storage, humidity 0-95% RH
- non condensating |
|
Alarm Relais: |
1 relais is standard, 1 A at 250 VAC, 5 A at 30 VDC
Option: 2 additional relais. (Relais 1+2: change over contact, Relay
3: normally open contacts) |
|
Analogue output: |
Option. 4-20 mA, max. 22 mA, Temperature drift <0.02% FS,
Accuracy: worst 0.4% FS, typical 0.2% FS at 25°C ambient temperature
Max. 500 Ohm, resolution 0.02 mA |
|
Inputs
for Thermo Couples |
Accuracy including
linearisation |
|
Range °C |
worst case |
typical at 25°C |
|
Type J |
-210...+1200°C |
±1,0°C |
±0,5°C |
|
Type K |
-270...+1372°C |
±1,0°C |
±0,5°C |
|
Type T |
-270...+400°C |
±1,0°C |
±0,5°C |
|
Type N |
-200...+1300°C |
±1,0°C |
±0,5°C |
|
Type S |
-50...+1767°C |
±2,0°C |
±1,2°C |
|
Type R |
-50...+1767°C |
±2,0°C |
±1,2°C |
|
Inputs
for Resistance Thermometer RTD |
Accuracy including
linearisation |
|
Range °C |
worst case |
typical at 25°C |
|
Pt 100 (Alpha = 385) |
-200...+850°C |
±0,8°C |
±0,5°C |
|
Pt 100 (Alpha = 392) |
-200...+457°C |
±0,8°C |
±0,5°C |
|
Inputs
for Voltage & Current |
Skaling: any portion of the display range, decimal point in any
position
Accuracy: worst ±0.1%, typical ±0.05% at 25°C
Drift with temp. < 0.02%.
Impedance (Ohm): <5 (mA), > 100M (mV), >1M (Volt) |
|
±20 mA |
|
±100 mV |
|
Order-Code:
|
211.1.096. |
0 |
1 |
0 |
1 |
.0 |
| |
Analogue output:
0 = without
1 = with |
No. Relais:
1 = 1 (standard)
2 = total 2 pcs..
3 = total 3 pcs. |
Config. buttons:
0 = hidden
1 = visible |
Power supply:
1 = 90-256 VAC
2 = 10-32 VDC/VAC |
Display:
.0 = LED red
.1 = LED green |
Example:
211.1.096.1111.0 = Type 211, with analogue output, 1 alarm
relay, visible configuration buttons, 90-256 VAC, with red LED |
|
NEW:
Configuration software available for download.(ZIP-file, you need
PKUNZIP
for de-compressing the files). Enables configuration of 220 series instruments
with Perconal Computer. The configuration software is running under MS
Windows 3.x or higher.
|
|